The 3400 pump has wide appeal in the nuclear medicinenuclear cardiology areas because of its wide range of features. Graseby 3150 syringe pump manufacturer specifications. To use the injection pump shield, simply open the shield cover, insert the syringe from behind the shield, connect the i. Mum was under hospital admission when she passed, however the day she died, the staff administrated a morphine syringe driver into the thigh. The graseby ms 16a syringe drivers is a nonsterile devices. Graseby 3400 syringe pump manufacturer specifications. Graseby 2000 syringe pump range, infusion smiths medical. The graseby ms 26 s yringe driver is for daily rate infusions of 1 day or longer and has a green label. Graseby medical model ms16a desferal therapy syringe pump the ms16a syringe driver is a popular, cost effective and reliable device for low volume subcutaneous or iv infusions. Syringepumppro software takes control of your pumps, automating your fluid flows, guaranteeing repeatability. The graseby syringe driver has been in common use for many years where subcutaneous infusion of medications for palliative patients, particularly in the community, is required.
Its popularity relates to its ease of use for practitioners, portability, and relatively low cost in comparison with other available infusion devices. A syringe pump is a small, batterypowered pump that delivers medication subcutaneously under the skin at a constant rate throughout the day and night. Unfollow graseby syringe pump to stop getting updates on your ebay feed. A macmillian nurse later visited mum and the driver was changed to also include antisickness drugs as well as the pain releif and then within about 45 hours mum had passed away. The pump is simple to operate, reliable and is of general. Used, graseby 3300 syringe pump with key driver pc. The ms 16a is known as the hourly rate syringe driver.
Use only syringe manufacturers and sizes listed in the technical specifications of this manual. Graseby 2000 syringe pump range infusion products syringe infusion. The graseby ms16a syringe pump, showing the two rotary controls for adjusting the rate in mm h. Please contact us to determine a pump model that will meet your specifications. Graseby 3300 syringe driver pump fluid administration.
Please see oem starter kit and oem net below computer controllable. Download the syringe pump literature product brochure. When triggered by a sensor enable pulse from the main processor, q10 turns on so. Graseby 3300 syringe pump used in very good graseby omnifuse pump with key. It is the most costeffective device for this procedure using inexpensive syringes and subcutaneous infusion sets the graseby ms16a syring infusion pump is ideal for our subcutaneous patients. Syringe pump advanced precision programmable syringe. Guidelines for syringe driver management in palliative care in. Graseby medical model ms16a desferal therapy syringe pump. There are two main device options to replace the graseby, they are the ad syringe driver supplied by cardinal health also known as the alaris. T34 syringe driver instruction video for oxfordshire duration. Rather than transmit this information as a series of eight pulses one after the other serial, it can be transmitted down eight lines at once a computercontrolled syringe driver 671 syringe driver type ms 16a s3 graseby fig. Graseby 3300 syringe driver download remove and retain the two screws that hold the sensors board in place.
Service technicians forum user manual for graseby 3100 syringe pump rajagopal geethu zigma meditech india private limited can i get a copy of the user or service. This identified relevant websites relating to syringe driver management. A syringe pump can also be used over a shorter period of time while the patient needs a specific medicine. Concerns were also raised by the health and disability commissioner after a number of cases occurred due to errors with syringe driver use. A lead glass viewing window allows the technologist to ensure the dose is being properly administered throughout the entire procedure.
The following are example flow rates for a sample of syringes with the model ne single syringe pump. This syringe driver is used throughout the world for the infusion of desferal. Ms26 syringe driver technical service manual issue 6 february 2005 page i smiths medical. Designed with safety in mind, the graseby smiths medical omnifuse pca breaks new ground in syringe pump design. The curlin medical pump can be used for intravenous, epidural, or subcutaneous therapies. Graseby tek dsp goring kerr metal detector operator interface panel display. The pump was in use on this same pt for 6 weeks and was infusing haloperidol and midazolam. This smiths medical graseby 3000 modular infusion pump is used and in excellent condition. Graseby infusion pumps have been trusted by healthcare professionals for over 30 years both pumps deliver medication as a continuous infusion at rate between 0.
Graseby syringe driver guidelines queensland health. Medwow medical equipment anesthesiology syringe pump graseby 3400 manufacturer specifications manufacturer specifications 3400, graseby please note. The graseby ms 16a syringe driver is for hourly rate infusions between 30 minutes and 24 hours and has a blue label. The graseby 2000 range of syringe pumps provide reliable and precise infusions for a range of clinical therapy areas. The literature was rated for its level of evidence using the joanna briggs. If required, a preset volume to be infused vtbi may be. Ms16a syringe driver rate set in mmhr typical infusion range 30mins 60 hrs variable speed 099 mmhr syringe driver packed set syringe driver, shoulder holster, syringe cover, rate adjuster, battery and instruction manual. Volumetric iv specialty sets, infusion smiths medical. Reduce wastage of expensive components and operator time. Aladdin infusion pump top selling programmable single syringe pump.
Pump application ap 14 syringe pump is designed for precise dosage of drugs and infusion fluids to the patient. A syringe driver or syringe pump is a small infusion pump some include infuse and withdraw capability, used to gradually administer small amounts of fluid with or without medication to a patient or for use in chemical and biomedical research applications include electrospinning, electrospraying, microdialysis, microfluidics, dispensingdilution, organtissue perfusion and. Why use the graseby medical model 3400 nuclear medicine syringe pump. Specifically developed for patient controlled analgesia pca, omnifuse pca meets the needs of todays demanding pain management therapies. Guidelines for syringe driver management in palliative. Both of these pumps have been approved as fit for purpose by the syringe driver advisory group.
It can infuse virtually any iv drug with a range from 0. User facility reported that the pump infused more quickly than programmed. Graesby 3000 safety checks 31 kb download prohibited by smiths medical. Graseby 3100 service manual 780 kb download prohibited by smiths medical. Failure to use the correct model driver may result in an inaccurate delivery of medication, resulting in patient injury or. For the past 30 years, these have been used widely in hospitals, hospices, aged care settings and the community. The ms16a syringe driver is a popular, cost effective and reliable device for low volume subcutaneous or iv infusions. None of the equipment posted for sale on is owned by medwow, should you have any questions regarding a specific item, please direct them to the appropriate seller by making. The graseby ms16a syringe driver is a popular, cost effective and reliable device for low volume subcutaneous or iv infusions.
The most common type of syringe driver in use in new zealand have been the graseby ms16a and the ms26. The graseby ms16a pump is ideal for subcutaneous patients. When and how to use a syringe driver in palliative. Graseby omnifuse pca syringe pump signature emergency. Pressure and viscosity also determine proper pump selection. Failure to use the correct model driver may result in an inaccurate delivery of medication, resulting in patient injury or death. It is the most costeffective device for this procedure using inexpensive syringes and subcutaneous infusion sets. To prevent serious damage to the driver, it must not be immersed. If your manual is a year or more old, contact smiths medical to see if a newer manual is available. However, the graseby syringe drivers no longer meet the minimum. Medwow medical equipment anesthesiology syringe pump graseby 3150 manufacturer specifications manufacturer specifications 3150, graseby please note. World precision instruments laboratory syringe pumps. The graseby syringe driver has been gradually phased out of use as it was not tamperproof.
1544 808 615 1524 377 795 602 301 416 1256 452 909 259 844 413 871 883 297 298 1012 163 1481 82 1286 824 208 373